Hourly PM2.5 data

Air Quality Monitoring - 2016 (grouped by pollutant)

Created 11/11/2025

Updated 11/11/2025

Period of reporting: 1 January to December 2016
Monitoring sites: Cannon Hill, Luscombe, Lytton, Rocklea, South Brisbane, Springwood, Wynnum North, Wynnum West (South East Queensland); Jondaryan (Jondaryan); Boat Creek, Boyne Island, Clinton, Fisherman's Landing, South Gladstone, Targinie (Gladstone region)

Measurement units: micrograms per cubic metre (ug/m^3)

Measurement technique (Springwood - until 15 February): Tapered Element Oscillating Balance (TEOM) Model 1400AB operated in accordance with AS 3580.9.8
- Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
- Reported values are unadjusted instrument output values as per the requirements of the Air NEPM Technical Paper on Monitoring for Particles as PM2.5.
- Negative hourly PM2.5 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.

Measurement technique (Lytton, Wynnum North, Wynnum West): Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-D operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements)
- Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
- Reported concentrations are uncorrected instrument output values.
- Negative hourly PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.

Measurement technique (Cannon Hill, Luscombe - until 6 May, Rocklea, South Brisbane, Springwood - from 25 February, Jondaryan, Boat Creek, Boyne Island, Clinton, South Gladstone,Targinie): Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13
- The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.
- Reported concentrations are uncorrected instrument output values.
- The reported PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.
- Negative hourly PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.

Source

This data file or API can be downloaded from:

https://www.data.qld.gov.au/dataset/7844efd9-5116-4dba-8459-c79703d82b39/resource/b5cde0fa-1063-41af-a01d-64e46a221985/download/pm2-5qld2016.csv