Flinders View (Ipswich, South East Queensland)...
Period of operation: 1 January to 31 December 2017
Site location: Latitude: -27.6528; Longitude: 152.7741
AS/NZS 3580.1.1 site classification: Neighbourhood
AS/NZS 3580.1.1 compliance (pollutants): Complies, except for:
- Trees above the height of inlet within 10 metres of the monitoring site.
AS/NZS 3580.14 compliance (meteorology): Complies, except for:
- Located on western side of slope below a ridge running northeast-southeast.
- Trees within 10 metres of the monitoring site (below height of wind sensor).
- Temperature and relative humidity sensors located 10 metres above ground level.
- Rainfall measured by acoustic sensor
Wind: Ultrasonic sensor
- Height above ground level: 10 metres.
- The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.
Temperature: Capacitive ceramic sensor
- Height above ground level: 10 metres.
Relative humidity: Capacitive thin film polymer sensor
- Height above ground level: 10 metres.
Rainfall: Vaisala RAINCAP® precipitation sensor
- Height above ground level: 10 metres.
Barometric pressure: Capacitive silicon sensor
- Height above ground level: 10 metres.
Ozone: UV absorption analyser operated in accordance with AS/NZS 3580.6.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Sulfur dioxide: Ultraviolet fluorescence analyser operated in accordance with S/NZS 3580.4.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
PM10: Tapered Element Oscillating Microbalance (TEOM) Model 1405 operated in accordance with AS/NZS 3580.9.16 (excluding FDMS requirements)
- Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
- Reported concentrations are uncorrected instrument output values.
- Negative hourly PM10 concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.
Visibility-reducing particles: Nephelometer operated in accordance with AS/NZS 3580.12.1
- Detector spectral response centred at 530 nm.
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
Source
This data file or API can be downloaded from:
https://www.data.qld.gov.au/dataset/4dcbe485-760a-4901-9757-d220c5fbd072/resource/a0524f61-cfce-4e15-8067-f32485d21534/download/flindersviewaq2017.csvResources
There are no views created for this resource yet.
Data Dictionary
Additional Information
| Field | Value |
|---|---|
| Data last updated | May 19, 2025 |
| Metadata last updated | November 11, 2025 |
| Format | CSV |
| License | Not Specified |
| Datastore active | True |
| Datastore contains all records of source file | False |
| Has views | False |
| Hash | a81ad97e593048eaa80ca9a6e6693552 |
| Id | a0524f61-cfce-4e15-8067-f32485d21534 |
| Mimetype | text/csv |
| Package id | 4dcbe485-760a-4901-9757-d220c5fbd072 |
| Position | 12 |
| State | active |
| Zip extract | False |
| Size | Unknown |
| ID | a0524f61-cfce-4e15-8067-f32485d21534 |
| Harvested | True |
| Package ID | 4dcbe485-760a-4901-9757-d220c5fbd072 |
| State | active |