Cannon Hill (South East Queensland) 2019...
Period of operation: 1 January to 31 December 2019 (particle measurements impacted by car park development earthworks next to station from 1 October to 31 December)
Site location: Latitude: -27.4654; Longitude: 153.0872
AS/NZS 3580.1.1 site classification: Neighbourhood
AS/NZS 3580.1.1 compliance (pollutants): Complies fully
AS/NZS 3580.14 compliance (meteorology): Complies, except for:
- Temperature and relative humidity sensors located 10 metres above ground level.
- Rainfall measured by acoustic sensor
Wind sensor: Ultrasonic sensor
- The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.
Temperature: Capacitive ceramic sensor
- Height above ground level: 10 metres.
Relative humidity: Capacitive thin film polymer sensor
- Height above ground level: 10 metres.
Rainfall: Vaisala RAINCAP® precipitation sensor.
- Height above ground level: 10 metres.
Barometric pressure: Capacitive silicon sensor.
- Height above ground level: 10 metres.
Ozone: UV absorption analyser operated in accordance with AS/NZS 3580.6.1
- Instrument output offset and/or scaled based on calibration and daily zero/span response data.
PM10/PM2.5: Dichotomous Tapered Element Oscillating Balance (TEOM) Model 1405-DF fitted with Filter Dynamics Measurement System (FDMS) operated in accordance with AS/NZS 3580.9.13
- The FDMS system compensates for the loss of semi-volatile components from the collected particulate matter.
- Reported concentrations are uncorrected instrument output values.
- The reported PM10 and PM2.5 concentrations are calculated from running 1-hour average concentrations updated at six minute intervals.
- Negative hourly PM10/PM2.5 concentrations down to -5 µg/m^3 resulting from instrument noise at low particle concentrations are reported.
TSP: Tapered Element Oscillating Microbalance (TEOM) Model 1405 fitted with TSP inlet and operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements)
- Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
- Reported concentrations are uncorrected instrument output values.
- Negative hourly TSP concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.
Source
This data file or API can be downloaded from:
https://www.data.qld.gov.au/dataset/827a95bc-7160-4510-9a75-b4b4d22042a6/resource/edd15a43-c11b-4f8b-aaf6-aa99d42ccb55/download/cannonhill-aq-2019.csvResources
There are no views created for this resource yet.
Data Dictionary
Additional Information
| Field | Value |
|---|---|
| Data last updated | April 10, 2025 |
| Metadata last updated | November 11, 2025 |
| Format | CSV |
| License | Not Specified |
| Ckan url | https://www.data.qld.gov.au |
| Datastore active | True |
| Datastore contains all records of source file | True |
| Has views | False |
| Hash | 47bdc625a8e276a349cf785647843b4d |
| Id | edd15a43-c11b-4f8b-aaf6-aa99d42ccb55 |
| Ignore hash | False |
| Mimetype | text/csv |
| Original url | https://www.data.qld.gov.au/dataset/827a95bc-7160-4510-9a75-b4b4d22042a6/resource/edd15a43-c11b-4f8b-aaf6-aa99d42ccb55/download/cannonhill-aq-2019.csv |
| Package id | 827a95bc-7160-4510-9a75-b4b4d22042a6 |
| Position | 7 |
| Resource id | edd15a43-c11b-4f8b-aaf6-aa99d42ccb55 |
| State | active |
| Task created | 2025-04-02 00:50:09.134311 |
| Zip extract | False |
| Size | Unknown |
| ID | edd15a43-c11b-4f8b-aaf6-aa99d42ccb55 |
| Harvested | True |
| Package ID | 827a95bc-7160-4510-9a75-b4b4d22042a6 |
| State | active |