Parkwood (Gold Coast, South East Queensland)...

Air Quality Monitoring - 2023

Created 11/11/2025

Updated 11/11/2025

Period of operation: 8 June (site established) to 31 December 2023
Site location: Latitude: -27.9535; Longitude: 153.3475
AS/NZS 3580.1.1 site classification: Peak (roadside)
AS/NZS 3580.1.1 compliance (pollutants): Complies fully
AS/NZS 3580.14 compliance (meteorology): Complies, except for:

  • Temperature and relative humidity sensors located 10 metres above ground level.

Wind: Ultrasonic sensor

  • Height above ground level: 10 metres.

  • The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.

Temperature: Capacitive ceramic sensor.

  • Height above ground level: 10 metres.

Relative humidity: Capacitive thin film polymer sensor.

  • Height above ground level: 10 metres.

Barometric pressure: Capacitive silicon sensor.

  • Height above ground level: 10 metres.

Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1

  • Instrument output offset and/or scaled based on calibration and daily zero/span response data.

Carbon monoxide: Infrared absorption analyser operated in accordance with AS 3580.7.1

  • Instrument output offset and/or scaled based on calibration and daily zero/span response data.

PM10/PM2.5: Scattered light spectrometry (TAPI Model 640X) operated in accordance with USEPA equivalence method designation requirements

  • Reported concentrations are uncorrected instrument output values.