North Maclean (South East Queensland) 2009...

Air Quality Monitoring - 2009

Created 12/11/2025

Updated 12/11/2025

Period of operation: 1 January to 31 December 2010
Region: South East Queensland
Site location: Latitude: -27.7708; Longitude: 153.0300
AS/NZS 3580.1.1 site classification: Background
AS/NZS 3580.1.1 compliance (pollutants): Complies fully
AS/NZS 3580.14 compliance (meteorology): Complies fully
Wind: Ultrasonic sensor

  • Height above ground level: 10 metres.
  • The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.

Temperature: Platinum resistance sensor
Relative humidity: Capacitive thin film polymer sensor
Ozone: UV absorption analyser operated in accordance with AS/NZS 3580.6.1

  • Instrument output offset and/or scaled based on calibration and daily zero/span response data.

Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1

  • Instrument output offset and/or scaled based on calibration and daily zero/span response data.