Cannon Hill (South East Queensland) 2023...

Air Quality Monitoring - 2023

Created 11/11/2025

Updated 11/11/2025

Period of operation: 1 January to 31 December 2023
Site location: Latitude: -27.4654; Longitude: 153.0872
AS/NZS 3580.1.1 site classification: Neighbourhood
AS/NZS 3580.1.1 compliance (pollutants): Complies fully
AS/NZS 3580.14 compliance (meteorology): Complies, except for:

  • Temperature and relative humidity sensors located 10 metres above ground level.
  • Rainfall measured by acoustic sensor

Wind sensor: Ultrasonic sensor

  • The wind direction sensor is aligned to magnetic north. The reported wind direction is referenced to true north by application of a magnetic declination correction of +11 degrees to the sensor output value.

Temperature: Capacitive ceramic sensor

  • Height above ground level: 10 metres.

Relative humidity: Capacitive thin film polymer sensor

  • Height above ground level: 10 metres.

Rainfall: Vaisala RAINCAP® precipitation sensor.

  • Height above ground level: 10 metres.

Barometric pressure: Capacitive silicon sensor.

  • Height above ground level: 10 metres.

Ozone: UV absorption analyser operated in accordance with AS/NZS 3580.6.1

  • Instrument output offset and/or scaled based on calibration and daily zero/span response data.

Oxides of nitrogen: Chemiluminescence analyser operated in accordance with AS/NZS 3580.5.1

  • Instrument output offset and/or scaled based on calibration and daily zero/span response data.

PM10/PM2.5: Scattered light spectrometry (TAPI Model 640X) operated in accordance with USEPA equivalence method designation requirements

  • Reported concentrations are uncorrected instrument output values.

TSP: Tapered Element Oscillating Microbalance (TEOM) Model 1405 fitted with TSP inlet and operated in accordance with AS/NZS 3580.9.13 (excluding FDMS requirements)

  • Measurement values do not compensate for loss of semi-volatile components from the collected particulate matter.
  • Reported concentrations are uncorrected instrument output values.
  • Negative hourly TSP concentrations less than -0.5 µg/m^3 are removed and concentrations between -0.5 µg/m^3 and 0.0 µg/m^3 are set to 0.0 µg/m^3.

Source

This data file or API can be downloaded from:

https://www.data.qld.gov.au/dataset/1e627b1a-5ac4-440e-bb78-7c7f2537b2de/resource/707c3ce6-b84d-4e87-8d2c-ab36fede88f6/download/cannonhill-aq-2023.csv